Title :
An experimental research of small power MH lamps operating in open-loop
Author :
Zhang, Weiping ; Zhang, Dongyan ; Sun, Zhefeng ; Zhang, Xiaoqiang
Author_Institution :
Coll. of Inf. Eng., North China of Univ. Technol., Beijing, China
Abstract :
A new open-loop measurement system has been built up to test the stability of metal halide (abbr. MH) lamps in this paper. Based on the new measurement system, a lot of small power MH lamps (70 W) have been tested and arrived at the followings conclusions: 1) the acoustic resonance of MH lamp is caused by itself while it operates in high frequency; 2) the stable operating frequency range is about under 10 kHz when the lamps are driven by the square-wave current; 3) the transform times, including rise-time and fall-time, of the high frequency square-wave current makes big effect on the lamp´s stability. The experiments show that reducing the transform time will improve the lamp´s stability; 4) with operating frequency increasing, the range of dimming would reduce to make sure it working in stable.
Keywords :
metal vapour lamps; open loop systems; acoustic resonance; dimming; metal halide lamps; open-loop measurement system; power 70 W; small power MH lamps; Acoustic measurements; Acoustic testing; Electric variables measurement; Electronic ballasts; Fluorescent lamps; Frequency; High intensity discharge lamps; Plasma measurements; Resonance; Stability; Open-Loop; Small Power MH Lampst;
Conference_Titel :
Power Electronics and Drive Systems, 2009. PEDS 2009. International Conference on
Conference_Location :
Taipei
Print_ISBN :
978-1-4244-4166-2
Electronic_ISBN :
978-1-4244-4167-9
DOI :