DocumentCode :
3192972
Title :
Potential value of electrocardiogram and photoplethysmogram for non-invasive blood pressure estimation during exercise
Author :
In Cheol Jeong ; Finkelstein, Joseph
Author_Institution :
Sch. of Med., Chronic Disease Inf. Program, Johns Hopkins Univ., Baltimore, MD, USA
fYear :
2013
fDate :
3-7 July 2013
Firstpage :
2304
Lastpage :
2307
Abstract :
Blood pressure (BP) monitoring is required to ensure safety of home-based exercise in seniors. Pulse transit time (PTT) defined as the time it takes a pulse wave to travel between two arterial sites is considered to be inversely proportional to BP. Different approaches have been described to calculate PTT using photoplethysmogram (PPG) and electrocardiogram (ECG) however it is not clear which approach produces better BP estimates. The purpose of this study was to compare potential value of different approaches for calculating PTT and other derivatives of PPG and ECG described in the literature for assessing BP during exercise. Three calibration points were collected from five study participants at different levels of exertion on three different days. A high precision automated BP monitor was used to obtain reference BP. A correlation matrix between PPG/ECG derivatives and the reference BP values was analyzed. Based on the bivariate correlation analysis, PPG/ECG derivatives that demonstrated the most prominent association with reference BP were identified. The results of the study confirmed the value of individualized calibration for BP estimation using PTT and identified optimal means to derive it from PPG and ECG.
Keywords :
biomechanics; blood pressure measurement; calibration; correlation methods; electrocardiography; geriatrics; patient monitoring; photoplethysmography; PPG-ECG derivative; arterial site; bivariate correlation analysis; blood pressure monitoring; calibration point; correlation matrix; electrocardiogram; exercise BP; exercise exertion level; high precision automated BP monitor; home-based exercise safety; individualized calibration value; noninvasive blood pressure estimation; photoplethysmogram; pulse transit time calculation; pulse wave; reference BP value; senior exercise; Biomedical monitoring; Blood pressure; Correlation; Electrocardiography; Estimation; Foot; Monitoring;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location :
Osaka
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2013.6609998
Filename :
6609998
Link To Document :
بازگشت