• DocumentCode
    3193700
  • Title

    Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse controlled inverters

  • Author

    Kaufhold, M.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • fYear
    1995
  • fDate
    22-25 Oct 1995
  • Firstpage
    254
  • Lastpage
    257
  • Abstract
    When induction machines are fed by fast switching inverters, their interturn insulation is electrically more stressed than in the conventional feed. When inverters are used steep voltage pulses of high repetition frequency occur. This can cause partial discharges (PDs) leading to insulation failure. The PD inception voltage and velocity of the resulting electrical ageing depend on the voltage characteristic, insulation design and temperature. These relations were investigated using laboratory models of interturn insulation, semiconductor-based pulse generator and as PD detector an UV-sensitive photo multiplier tube
  • Keywords
    PWM invertors; ageing; asynchronous machines; electric breakdown; failure analysis; machine insulation; partial discharges; PD inception voltage; electrical ageing; failure mechanism; fast switching inverters; induction machines; insulation design; insulation failure; interturn insulation; low voltage electric machines; partial discharges; pulse controlled inverters; temperature; voltage characteristic; Aging; Dielectrics and electrical insulation; Failure analysis; Feeds; Frequency; Induction machines; Low voltage; Partial discharges; Pulse inverters; Temperature dependence;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1995. Annual Report., Conference on
  • Conference_Location
    Virginia Beach, VA
  • Print_ISBN
    0-7803-2931-7
  • Type

    conf

  • DOI
    10.1109/CEIDP.1995.483711
  • Filename