DocumentCode :
3195064
Title :
Lepton Collider Operation with Constant Currents
Author :
Wienands, U.
Author_Institution :
SLAC, Stanford, CA, USA, uli@slac.stanford.edu
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
149
Lastpage :
153
Abstract :
Electron-positron colliders have been operating in a top-up-and-coast fashion with a cycle time depending on the beam life time, typically one or more hours. Each top-up involves ramping detector systems in addition to the actual filling time. The loss in accumulated luminosity may be 20-50%. During the last year, both B-Factories have commissioned a continuous-injection mode of operation in which beam is injected without ramping the detector, thus raising luminosity integration by always operating at peak luminosity. Constant beam currents also reduce thermal drift and trips caused by change in beam loading. To achieve this level of operation, special efforts were made to reduce the injection losses and also to implement gating procedures in the detectors, minimizing dead time. Beam collimation can reduce injection noise but also cause an increase in background rates. A challenge can be determining beam lifetime, important to maintain tuning of the beams.
Keywords :
Background noise; Colliding beam devices; Collimators; Detectors; Filling; Linear particle accelerator; Noise reduction; Optical modulation; Switches; Thermal loading;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590385
Filename :
1590385
Link To Document :
بازگشت