DocumentCode
3197545
Title
Numi Proton Kicker Extraction System
Author
Jensen, C.C. ; Krafczyk, G.E.
Author_Institution
Fermilab, Batavia IL 60510, USA
fYear
2005
fDate
16-20 May 2005
Firstpage
692
Lastpage
694
Abstract
This system extracts up to 9.6 µ s of 120 GeV beam every 1.87 seconds for the NuMI beamline neutrino experiments. A pulse forming network consisting of two continuous wound coils and 68 capacitors was designed and built to drive three kicker magnets. The field stability requirement is better than ± 1% with a field rise time of 1.52 μs. New kicker magnets were built based on the successful traveling wave magnets built for the Main Injector. Two of these magnets are in series which places a serious constraint on the rise time of the pulser. A forced cooling system using Fluorinert ® was designed for the magnet termination resistors to maintain the field flatness and amplitude stability.
Keywords
Capacitors; Coils; Large Hadron Collider; Magnets; Protons; Pulsed power supplies; Resistors; Stability; Voltage; Wounds;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN
0-7803-8859-3
Type
conf
DOI
10.1109/PAC.2005.1590530
Filename
1590530