• DocumentCode
    3198647
  • Title

    A physical layer for the CAN bus using modulated PLC

  • Author

    Davenport, David M. ; Hoctor, Ralph T.

  • Author_Institution
    General Electr. Global Res., NY, USA
  • fYear
    2005
  • fDate
    6-8 April 2005
  • Firstpage
    176
  • Lastpage
    180
  • Abstract
    In this paper, we describe a physical layer for the CAN bus using PLC. Our application is a low-data-rate sensor network used to monitor railroad crossing warning systems.
  • Keywords
    alarm systems; carrier transmission on power lines; controller area networks; railway safety; railways; sensors; CAN bus; low-data-rate sensor network; modulated power line communication; railroad crossing warning systems monitoring; Access protocols; Alarm systems; Logic; Monitoring; Physical layer; Programmable control; Signal design; US Department of Transportation; Voltage; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Line Communications and Its Applications, 2005 International Symposium on
  • Print_ISBN
    0-7803-8844-5
  • Type

    conf

  • DOI
    10.1109/ISPLC.2005.1430491
  • Filename
    1430491