Title :
Beam Diagnostics for the J-PARC Main Ring Synchrotron
Author :
Toyama, T. ; Arakawa, D. ; Hashimoto, Y. ; Lee, S. ; Miura, T. ; Muto, S. ; Hayashi, N. ; Toyokawa, R. ; Kishiro, J.
Author_Institution :
KEK, Tsukuba, Ibaraki, Japan, takeshi.toyama@kek.jp
Abstract :
Beam diagnostics: beam intensity monitors (DCCT SCT, FCT, WCM), beam position monitors (ESM), beam loss monitors (proportional chamber, air ion chamber), beam profile monitors (secondary electron emission, gas-sheet) have been designed, tested, and will be installed for the Main Ring synchrotron (MR) of J-PARC (Japan Proton Accelerator Research Complex). This paper covers the basic design principle and specification of each monitor of the MR and the beam transport line from 3 GeV rapid cycling synchrotron to the MR (3-50BT), with a stress on how to cope with high power beam (average circulation current of ∼13 A) and low beam loss operation (less than 0.5 W/m except a collimator, injection and extraction region). Some results of preliminary performance test using present beams and a radiation source will be reported.
Keywords :
Acceleration; Current measurement; Data mining; Extraterrestrial measurements; Particle beams; Radio frequency; Saturation magnetization; Soft magnetic materials; Synchrotrons; Testing;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1590624