• DocumentCode
    319940
  • Title

    Using synthetic M-mode imaging to measure temporal differences in left ventricular contraction patterns during ischemia

  • Author

    Lee, S.H. ; Saltzberg, M.T. ; Neumann, A. ; Wolfer, J. ; Soble, J.S. ; Roberge, J.

  • Author_Institution
    Dept. of Comput. Sci., Illinois Inst. of Technol., Chicago, IL, USA
  • fYear
    1997
  • fDate
    7-10 Sep 1997
  • Firstpage
    235
  • Lastpage
    238
  • Abstract
    Myocardial ischemia is usually identified by echocardiography using qualitative analysis of regional left ventricular (LV) endocardial excursion. This is often hampered by sub-optimal endocardial visualization and lack of quantitative standards and measurement techniques Ischemia changes the temporal pattern of LV contraction, and a method for quantifying changes in this temporal sequence would have clinical applicability. The authors developed and tested a computer-assisted technique using Synthetic M-mode (SMM) to measure the temporal variations in regional LV contraction. Using a LV short axis image, 6 SMM images were created through a user-defined LV center. The time to peak (t) contraction in 6 LV segments was then measured using the R-wave as a timing reference point. In the authors´ study of 15 closed chest dogs with induced regional ischemia, t was significantly prolonged only in those LV segments subtended by the occluded artery. Temporal SMM is a promising technique for defining temporal contraction patterns indicative of regional ischemia
  • Keywords
    echocardiography; image sequences; medical image processing; R-wave; closed chest dogs; computer-assisted technique; induced regional ischemia; left ventricular contraction patterns; medical diagnostic imaging; short axis image; suboptimal endocardial visualization; synthetic M-mode imaging; temporal contraction patterns; time to peak contraction; timing reference point; Echocardiography; Image segmentation; Ischemic pain; Measurement standards; Measurement techniques; Myocardium; Testing; Time measurement; Timing; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology 1997
  • Conference_Location
    Lund
  • ISSN
    0276-6547
  • Print_ISBN
    0-7803-4445-6
  • Type

    conf

  • DOI
    10.1109/CIC.1997.647874
  • Filename
    647874