DocumentCode :
3199510
Title :
Design and Initial Tests of a Gas Scattering Energy Monitor in the PEFP RFQ and DTL
Author :
Han, S.H. ; Cho, Y.S.
Author_Institution :
PEFP, KAERI, Daejon, 305-600, Korea, shhan@kaeri.re.kr
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
997
Lastpage :
999
Abstract :
We have developed a gas scattering energy monitor to measure the energy spectrum of the proton beam from 3 MeV to 20 MeV at the four-vane PEFP (Proton Engineering Frontier Project) RFQ and the DTL tank exit as a function of RF drive power. The energy monitor is comprised of a Xe scattering chamber, two collimators to reduce the beam intensity, and a surface barrier detector for measuring the proton energy. In order to measure the beam current simultaneously, a faraday cup is incorporated into the energy monitor. The calculated flux attenuation through the 0.2 mm diameter collimator is 2.7 x 10-3and the energy loss is 72 keV. We report on design details and multiple gas scattering of proton beams in Xe gas by using a SRIM code.
Keywords :
Collimators; Energy measurement; Monitoring; Particle beams; Power engineering and energy; Power measurement; Protons; Radio frequency; Scattering; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590637
Filename :
1590637