    Experimental studies of the influence of a resonance cavity in an axial vircator

  • Author

    Möller, Cecilia ; Elfsberg, Mattias ; Larsson, Anders ; Nyholm, Sten E.

  • Author_Institution
    Defence & Security, Syst. & Technol., Swedish Defence Res. Agency (FOI), Tumba, Sweden
  • fYear
    2009
  • fDate
    June 28 2009-July 2 2009
  • Firstpage
    86
  • Lastpage
    90
  • Abstract
    Experiments on an axial vircator are reported on. The design of the vircator allows adjustment of the cavity depth as well as of the way microwave radiation is extracted. The vircator is driven by a repetitive Marx generator operating in single shot mode. The microwave radiation is measured with a pair of free-field B-dot sensors. The maximum field strengths was registered when the bandwidth was very low, less than 1%.
  • Keywords
    cavity resonators; oscillators; pulse generators; pulsed power supplies; radiation monitoring; vircators; axial vircator; cavity depth; free-field B-dot sensors; microwave radiation; repetitive Marx generator; resonance cavity; single shot mode; Cathodes; Dielectrics; Electric breakdown; Flashover; Frequency; Geometry; Oscillators; Power electronics; Resonance; Testing;