DocumentCode
3202806
Title
Platinum IR sources for NDIR gas monitors
Author
Puton, J. ; Jasek, K. ; Siodlowski, B. ; Knap, A. ; Wisniewski, K.
Author_Institution
Inst. of Chem., Mil. Univ. of Technol., Warsaw, Poland
fYear
2001
fDate
2001
Firstpage
189
Lastpage
192
Abstract
The work presents the results of research of the new thermal IR sources to be used in NDIR (nondispersive infrared) gas monitors. The developed sources are adapted to direct modulation that consists of supplying the heater with variable voltage. Appropriate heat transfer makes it possible to reach a modulation frequency as high as 50 Hz. This value is considerably greater then the frequency limit that can be obtained for other IR sources. The sources show very good dynamic parameters, which makes them suitable for fast measurements of concentration
Keywords
gas sensors; heat transfer; heating elements; infrared sources; monitoring; optical sensors; platinum; 50 Hz; IR sources; NDIR gas monitors; Pt; concentration measurements; direct modulation; dynamic parameters; frequency limit; heat transfer; heater variable voltage supply; modulation frequency; nondispersive infrared gas monitors; platinum IR sources; thermal IR sources; Chemical technology; Frequency modulation; Heat transfer; Infrared heating; Insulation; Optical materials; Platinum; Pollution measurement; Radiation detectors; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronics Technology: Concurrent Engineering in Electronic Packaging, 2001. 24th International Spring Seminar on
Conference_Location
Calimanesti-Caciulata
Print_ISBN
0-7803-7111-9
Type
conf
DOI
10.1109/ISSE.2001.931051
Filename
931051
Link To Document