Protection Level During Extraction, Transfer and Injection into the LHC
Author :
Kain, V. ; Goddard, B. ; Schmidt, R. ; Wenninger, J.
Author_Institution :
CERN, Geneva, Switzerland
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1505
Lastpage :
1507
Abstract :
Failures during the LHC transfer and injection process cannot be excluded and beam loss with the foreseen intensities and energies will cause serious equipment damage. Consequences of equipment failures such as kicker erratics, power converter faults, etc. are investigated by means of a Monte Carlo based on MAD-X tracking with a full aperture model of the transfer line and the injection region. Geometrical and optical mismatch, orbit tolerances, mechanical tolerances for settings of protection elements, power converter ripples, misalignment of elements, etc. are all taken into account. The required performance of the protection system is discussed. The overall protection level for the LHC and the transfer lines during injection is presented.
Keywords :
Apertures; Collimators; Equipment failure; Geometrical optics; Large Hadron Collider; Monte Carlo methods; Power system modeling; Power system protection; Protons; Surveillance;