• DocumentCode
    3204396
  • Title

    Machine Protection System for Concurrent Operation of RHIC and BLIP

  • Author

    Wilinski, M. ; Bellavia, S. ; Glenn, J.W. ; Mausner, L.F. ; Unger, K.L.

  • Author_Institution
    BNL, Upton, NY
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    1754
  • Lastpage
    1756
  • Abstract
    The Brookhaven 200MeV linac is a multipurpose machine used to inject low intensity polarized protons for RHIC (Relativistic Heavy Ion Collider), as well as to inject high intensity protons to BLIP (Brookhaven Linac Isotope Producer), a medical isotope production facility. If high intensity protons were injected to RHIC by mistake, administrative radiation limits could be exceeded or sensitive electronics could be damaged. In the past, the changeover from polarized proton to high intensity proton operation has been a lengthy process, thereby never allowing the two programs to run simultaneously. To remedy this situation and allow concurrent operation of RHIC and BLIP, an active interlock system has been designed to monitor current levels in the AGS using two current transformers with fail safe circuitry and associated electronics to inhibit beam to RHIC if high intensity currents are detected.
  • Keywords
    Circuits; Current measurement; Current transformers; Hardware; Isotopes; Linear particle accelerator; Monitoring; Polarization; Protection; Protons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1590902
  • Filename
    1590902