DocumentCode :
3205536
Title :
Measurement of Transverse Echoes in RHIC
Author :
Fischer, W. ; Satogata, T. ; Tomas, R.
Author_Institution :
Brookhaven National Lab, Upton, NY 11973, USA, Wolfram.Fischer@bnl.gov
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1955
Lastpage :
1957
Abstract :
Beam echoes are a very sensitive method to measure diffusion, and longitudinal echo measurements were performed in a number of machines. In RHIC, for the first time, a transverse beam echo was observed after applying a dipole kick followed by a quadrupole kick. After application of the dipole kick, the dipole moment decohered completely due to lattice nonlinearities. When a quadrupole kick is applied at time τ after the dipole kick, the beam re-cohered at time 2τ thus showing an echo response. We describe the experimental setup and measurement results. In the measurements the dipole and quadrupole kick amplitudes, amplitude dependent tune shift, and the time between dipole and quadrupole kick were varied. In addition, measurements were taken with gold bunches of different intensities. These should exhibit different transverse diffusion rates due to intra-beam scattering.
Keywords :
Gold; Lattices; Particle beams; Performance evaluation; Physics; Plasma measurements; Pulse measurements; Pulsed power supplies; Time measurement; US Government;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590971
Filename :
1590971
Link To Document :
بازگشت