• DocumentCode
    3206410
  • Title

    Diagnostics for the LCLS Photoinjector Beamline

  • Author

    Limborg-Deprey, C. ; Dowell, D.H. ; Schmerg, J.

  • Author_Institution
    SLAC, 2575 Sand Hill Road, Menlo Park, CA 94025, USA, limborg@slac.stanford.edu
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    2089
  • Lastpage
    2091
  • Abstract
    Two spectrometers have been added to the LCLS photoinjector beamline. The first one will be located close to the exit of the Photoinjector RF gun. With this diagnostic, we will measure beam energy, energy spread (correlated and uncorrelated), possibly deleterious structure in the longitudinal phase space induced by longitudinal space charge force, and slice thermal emittance ... This extensive characterization of the 5MeV electron bunch will be made possible by combining this spectrometer with other diagnostics (YAG screens and Cerenkov Radiator). A second spectrometer located at the end of the beamline has been designed to characterize the 6-dimensional phase space of the 135MeV beam to be injected in the main accelerator. At that second spectrometer station, we will measure energy, energy spread (correlated and uncorrelated), longitudinal phase space, slice emittances ... Those last two measurements require using this spectrometer in combination with the transverse RF deflecting cavity and with the quadrupole scan emittance station. The designs of these two spectrometers have been supported by simulations from MAD and PARMELA.
  • Keywords
    Charge measurement; Current measurement; Electrons; Energy measurement; Force measurement; Phase measurement; Radio frequency; Space charge; Spectroscopy; Thermal force;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591018
  • Filename
    1591018