• DocumentCode
    3206484
  • Title

    Measurements of Field Decay and Snapback Effect on Tevatron Dipole and Quadrupole Magnets

  • Author

    Velev, G.V. ; Ambrosio, G. ; Annala, G. ; Bauer, P. ; Carcagno, R. ; DiMarco, J. ; Glass, H. ; Hanft, R. ; Kephart, R. ; Lamm, M. ; Martens, M. ; Schlabach, P. ; Sylvester, C. ; Tartaglia, M. ; Tompkins, J.

  • Author_Institution
    FNAL, Batavia, IL 60510, USA, velev@fnal.gov
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    2098
  • Lastpage
    2100
  • Abstract
    Since the beginning of 2002 an intensive measurement program has been performed at the Fermilab Magnet Test Facility (MTF) to understand dynamic effects in Tevatron magnets. Based on the results of this program a new correction algorithm was proposed to compensate for the decay of the sextupole field during the dwell at injection and for the subsequent field "snapback" during the first few seconds of the energy ramp. Beam studies showed that the new correction algorithm works better than the original one, and improves the Tevatron efficiency by at least 3%. The beam studies also indicated insufficient correction during the first 6s of the injection plateau where an unexpected discrepancy of 0.15 sextupole units of extra drift was observed. This paper reports on the most recent measurements of the Tevatron dipoles field at the beginning of the injection plateau. Results on the field decay and snapback in the Tevatron quadrupoles are also presented.
  • Keywords
    Error correction; Glass; Magnetic field measurement; Magnetic variables measurement; Performance evaluation; Persistent currents; Proposals; Superconducting magnets; Test facilities; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591022
  • Filename
    1591022