DocumentCode :
3206945
Title :
Beam Profile Measurement with Flying Wires at the Fermilab Recycler Ring
Author :
Hu, M. ; Carcagno, R. ; Krider, J. ; Lorman, E. ; Marchionni, A. ; Pischalnikov, Y. ; Pordes, S. ; Slimmer, D. ; Wilson, P.J. ; Zagel, J.
Author_Institution :
Fermilab, Batavia, IL 60510, U.S.A., martinhu@fnal.gov
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
2182
Lastpage :
2184
Abstract :
Flying wires were installed at the Fermilab Recycler Ring for transverse beam profile measurement for both proton and antiproton beams. The following note describes the system configuration, calibration and resolution of the flying wire system, interactions between the wires and the beam, as well as analysis of the transverse beam profile in the presence of a stochastic cooling system.
Keywords :
Calibration; Data acquisition; Data analysis; Dispersion; Particle beam measurements; Particle beams; Protons; Signal resolution; Timing; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1591050
Filename :
1591050
Link To Document :
بازگشت