DocumentCode
3207134
Title
Accurate calibration of CCD-cameras
Author
Beyer, Horst A.
Author_Institution
Inst. of Geodesy & Photogrammetry, ETH-Honggerberg, Zurich, Switzerland
fYear
1992
fDate
15-18 Jun 1992
Firstpage
96
Lastpage
101
Abstract
A basic review of the bundle adjustment with self-calibration is given. The mathematical model, parameter estimation, and quality analysis of calibration and positioning are covered. The calibration procedure, hardware, and testfield of an accuracy investigation with off-the-shelf CCD (charge-coupled device) camera, lens, and frame grabber are described. A relative accuracy in object space of 1 part in 30000 and an accuracy of 1/45 in image space were verified by independent measurements with theodolites
Keywords
CCD image sensors; calibration; parameter estimation; video cameras; CCD-cameras; accuracy; calibration procedure; frame grabber; image space; lens; object space; parameter estimation; positioning; quality analysis; self-calibration; Calibration; Charge coupled devices; Charge-coupled image sensors; Extraterrestrial measurements; Hardware; Lenses; Mathematical model; Parameter estimation; Testing; Theodolites;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Vision and Pattern Recognition, 1992. Proceedings CVPR '92., 1992 IEEE Computer Society Conference on
Conference_Location
Champaign, IL
ISSN
1063-6919
Print_ISBN
0-8186-2855-3
Type
conf
DOI
10.1109/CVPR.1992.223221
Filename
223221
Link To Document