• DocumentCode
    3207273
  • Title

    Three-phase regenerative front-ends for induction motor drives

  • Author

    Wheeler, N.J. ; Fraser, M.E. ; Alexander, T. ; Davies, T.S.

  • Author_Institution
    Heenan Drives Ltd., UK
  • fYear
    1997
  • fDate
    35573
  • Firstpage
    42522
  • Lastpage
    42527
  • Abstract
    There has been considerable interest in regenerative front ends for supplying the DC link in induction motor drives. An AC/DC converter comprising a three-phase inverter circuit with line inductors can achieve fully regenerative operation with near-sinusoidal line currents and near-unity power factor. This paper provides an overview of the topology, and outlines the most important design criteria. An attractive benefit of this kind of converter is the possibility of compensating for harmonics present on the supply voltage. In principle it is possible to “clean up” the local supply by drawing specific harmonics of input current, at a phase such as to cancel out these harmonics on the supply. A method for generating a 7th harmonic component in the input currents is described, and preliminary results are presented. The remaining obstacles to full implementation of this technique are outlined
  • Keywords
    induction motor drives; 7th harmonic component; AC/DC converter; DC link; design criteria; harmonics compensation; induction motor drives; input current harmonics; line inductors; near-sinusoidal line currents; near-unity power factor; supply voltage harmonics; three-phase inverter circuit; three-phase regenerative front-ends;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Update on New Power Electronic Techniques (Digest No: 1997/091), IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19970532
  • Filename
    642996