Title :
Efficiency of the Fermilab Electron Cooler´s Collector
Author :
Prost, L.R. ; Shemyakin, A.
Author_Institution :
FNAL, Batavia, IL 60510, U.S.A., lprost@fnal.gov
Abstract :
The newly installed Recycler Electron Cooling system (REC) at Fermilab [1] will work at an electron energy of 4.34 MeV and a DC beam current of 0.5 A in an energy recovery scheme. As a part of the Electron cooling project, the efficiency of the collector for the REC was optimized at a dedicated test bench to the level of relative current losses of 5·10-6. The paper discusses the test bench measurements for several distributions of a transverse magnetic field in the collector cavity.
Keywords :
Apertures; Cathodes; Cooling; Electron beams; Magnetic field measurement; Magnetic fields; Magnetic flux; Safety; Solenoids; Testing;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Conference_Location :
Knoxville, TN, USA
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1591119