DocumentCode
3208662
Title
An Induction Linac Test Stand
Author
DeHope, W.J. ; Goerz, D.A. ; Kihara, R. ; Ong, M.M. ; Vogtlin, G.E. ; Zentler, J.M.
Author_Institution
Lawrence Livermore National Laboratory, Livermore, CA 94551, U.S.A, dehope1@llnl.gov
fYear
2005
fDate
16-20 May 2005
Firstpage
2455
Lastpage
2457
Abstract
A single-cell test stand has been constructed at LLNL for studies aimed at improving the performance of the FXR radiographic facility. It has guided the development of diagnostics, pulsed power improvements, machine maintenance, and interface issues relevant to the entire accelerator. Based on this work, numerous machine improvements have been made which have resulted in demonstrable improvements in radiographic resolution and overall machine performance.
Keywords
Acceleration; Diagnostic radiography; Ion accelerators; Laboratories; Linear accelerators; Linear particle accelerator; Particle accelerators; Switches; Testing; Voltage;