• DocumentCode
    3209755
  • Title

    Detection of acoustic resonance in metal halide lamps

  • Author

    Hsieh, Yao C. ; Moo, Chin S. ; Chen, Hsien W. ; Soong, Ming J.

  • Author_Institution
    Power Electron. Lab., Nat. Sun Yat-Sen Univ., Kaohsiung, Taiwan
  • Volume
    2
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    881
  • Abstract
    To understand the occurrence of acoustic resonance in metal halide lamps is essential for an engineer to design a high-frequency electronic ballast. This paper proposes a simple method by measuring the lamp voltage for detecting the acoustic instability instead of observing the lamp arc by human eyes. The standard deviation in the lamp voltage is used as an index to determine the occurrence of acoustic resonance. With the index, the degree of the lamp arc instability can easily be specified. Experiments are carried out on various 70 W lamps to inspect the influence of the lamp type, the used hours, and the operating power on the frequency spectra of acoustic resonance
  • Keywords
    acoustic resonance; acoustic variables measurement; lamp accessories; metal vapour lamps; voltage measurement; 70 W; acoustic instability detection; acoustic resonance detection; frequency spectra; high-frequency electronic ballast; lamp arc instability; lamp voltage measurement; metal halide lamps; Acoustic measurements; Acoustic signal detection; Acoustical engineering; Design engineering; Electronic ballasts; Eyes; Humans; Lamps; Resonance; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 2001. Proceedings. ISIE 2001. IEEE International Symposium on
  • Conference_Location
    Pusan
  • Print_ISBN
    0-7803-7090-2
  • Type

    conf

  • DOI
    10.1109/ISIE.2001.931584
  • Filename
    931584