DocumentCode
3209755
Title
Detection of acoustic resonance in metal halide lamps
Author
Hsieh, Yao C. ; Moo, Chin S. ; Chen, Hsien W. ; Soong, Ming J.
Author_Institution
Power Electron. Lab., Nat. Sun Yat-Sen Univ., Kaohsiung, Taiwan
Volume
2
fYear
2001
fDate
2001
Firstpage
881
Abstract
To understand the occurrence of acoustic resonance in metal halide lamps is essential for an engineer to design a high-frequency electronic ballast. This paper proposes a simple method by measuring the lamp voltage for detecting the acoustic instability instead of observing the lamp arc by human eyes. The standard deviation in the lamp voltage is used as an index to determine the occurrence of acoustic resonance. With the index, the degree of the lamp arc instability can easily be specified. Experiments are carried out on various 70 W lamps to inspect the influence of the lamp type, the used hours, and the operating power on the frequency spectra of acoustic resonance
Keywords
acoustic resonance; acoustic variables measurement; lamp accessories; metal vapour lamps; voltage measurement; 70 W; acoustic instability detection; acoustic resonance detection; frequency spectra; high-frequency electronic ballast; lamp arc instability; lamp voltage measurement; metal halide lamps; Acoustic measurements; Acoustic signal detection; Acoustical engineering; Design engineering; Electronic ballasts; Eyes; Humans; Lamps; Resonance; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, 2001. Proceedings. ISIE 2001. IEEE International Symposium on
Conference_Location
Pusan
Print_ISBN
0-7803-7090-2
Type
conf
DOI
10.1109/ISIE.2001.931584
Filename
931584
Link To Document