• DocumentCode
    3209860
  • Title

    Development of high spatial resolution x-ray radiography system equipped with multiwalled carbon nanotube field emission cathode

  • Author

    Yabushita, Ryosuke ; Hata, Koichi

  • Author_Institution
    Mie Univ., Tsu
  • fYear
    2007
  • fDate
    8-12 July 2007
  • Firstpage
    61
  • Lastpage
    62
  • Abstract
    In this paper, newly developed high spatial resolution X-ray radiography system (HR-XRS) by modifying the compact SEM equipped with the MWCNT cathode former was reported. The X-ray images of the Cu 300 mesh were taken as a demonstration of the XRS. The resolution less than 1 mum was achieved. It is suggested that the MWCNT cathode is suitable one for the HR-XRS.
  • Keywords
    X-ray imaging; carbon nanotubes; cathodes; copper; electron field emission; image resolution; nondestructive testing; radiography; scanning electron microscopy; C; Cu; HR-XRS; MWCNT cathode; SEM; field emission cathode; high-spatial resolution X-ray radiography system; multiwalled carbon nanotube; Carbon nanotubes; Cathodes; Electron beams; Lenses; Radiography; Scanning electron microscopy; Spatial resolution; Tungsten; X-ray diffraction; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Vacuum Nanoelectronics Conference, 2007. IVNC. IEEE 20th International
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    978-1-4244-1133-7
  • Electronic_ISBN
    978-1-4244-1134-4
  • Type

    conf

  • DOI
    10.1109/IVNC.2007.4480931
  • Filename
    4480931