• DocumentCode
    3210593
  • Title

    Effect of series FACTS devices on distance protection

  • Author

    Satyanarayana, K. ; Prasad, B.K.V. ; Saikrishna, K.

  • Author_Institution
    PPDCET, Vijayawada, India
  • fYear
    2011
  • fDate
    20-22 July 2011
  • Firstpage
    36
  • Lastpage
    41
  • Abstract
    The increase in the line complexity, configuration and the power transmitted has introduced a number of problems in relation to protection. New techniques have become necessary to tackle these problems. Firstly it has become necessary to see that lines are not unnecessarily disconnected, but at the same time shorter operating times from protective relays are demanded on faulted sections to preserve the system stability. In this paper, discussion is made on the basic needs of protective systems, the various schemes of protection and the importance of distance protection in power system. Next it deals with various distance relay characteristics such as Mho, Ohm, Quadra mho, Quadrilateral, Elliptical, lentical and Ova. The constructional features of each type of distance re lay, the behavior and performance of various distance relays had been analysed. The variation in the operation of Distance Relay for multi-terminal configuration, effect of arc resistance, tower footing resistance, resistive reach is obtained. Finally the effect of Series Flexible Alternating Current Transmission System(FACTS) devices on the performance and operational characteristics of the Distance Relays will be observed. The entire simulations are done by using Mipower software to incorporate all the above features and graphical display in transient stability analysis. These studies give us the latest trends in the transmission line protection.
  • Keywords
    flexible AC transmission systems; power system transient stability; power transmission protection; relay protection; Mipower software; arc resistance; distance protection; distance relay characteristics; distance relays; faulted sections; graphical display; line complexity; multiterminal configuration; operating times; operational characteristics; power system; protective relays; protective systems; resistive reach; series FACTS devices; series flexible alternating current transmission system; system stability; tower footing resistance; transient stability analysis; transmission line protection; Distance protection; FACTS; Relays; Zones;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Sustainable Energy and Intelligent Systems (SEISCON 2011), International Conference on
  • Conference_Location
    Chennai
  • Type

    conf

  • DOI
    10.1049/cp.2011.0331
  • Filename
    6143279