DocumentCode :
3210901
Title :
A new approach for calculation of minimum miscibility pressure based on a multiple-mixing-cell model
Author :
Jungang, Li
Author_Institution :
Coll. of Pet. Eng., Northeast Pet. Univ., Daqing, China
Volume :
1
fYear :
2010
fDate :
13-14 Sept. 2010
Firstpage :
406
Lastpage :
409
Abstract :
A key parameter in the design of a miscible gas injection process is the minimum miscibility pressure (MMP), the minimum pressure at which the local displacement efficiency approaches 100%. For nc components, it is well known that the compositional path of the process, i.e. path in the compositional space representing the total composition, consists of nc-1 key tie lines and nc-2 non tie lines. The multi-contact miscibility of this process is controlled by a sequence of nc-1 key tie lines: the initial tie line, the injection tie line, and -3 crossover tie lines. The MMP is therefore the lowest pressure at which any of the key tie lines is a critical tie line. There are many criteria that can be used to determine the MMP. In our recent work, we demonstrate that zero key tie-line length is a robust criterion for determining the MMP. Upon increasing pressure, the pressure at which the tie-line length of one of the nc-1 key ties lines reaches zero is the MMP. Therefore, the problem reduces to how to identify key tie lines. Currently, the only method proposed to identify key tie lines is the tie-line intersection approach, which states that any two adjacent key tie lines must intersect. By solving 2nc (nc-1) equations, all nc-1 key tie lines can be found. The main problems for this approach are the determination of initial guesses and the non-uniqueness of the solution. In this work, a new approach based on our multiple-mixing-cell model is proposed to identify the key tie lines, and therefore to calculate the MMP. This finding leads to a new approach to identifying the key tie lines. This approach provides a unique solution to find all the key tie lines and is therefore particularly suitable for gas injection studies.
Keywords :
flow simulation; gas industry; mixing; multiphase flow; solubility; MMP; minimum miscibility pressure calculation; miscible gas injection process; multicontact miscibility; multiple-mixing-cell model; zero key tie-line length;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computational Intelligence and Natural Computing Proceedings (CINC), 2010 Second International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-7705-0
Type :
conf
DOI :
10.1109/CINC.2010.5643807
Filename :
5643807
Link To Document :
بازگشت