Title :
Automatic Control Method of NO Removal by a Combination of Ozone Injection and Exhaust Gas Recirculation
Author :
Yoshioka, Yoshio ; Kondo, Hiroaki ; Tabata, Yasuharu ; Hatakenaka, Hayato ; Nakada, Katsushi
Author_Institution :
Kanazawa Inst. of Technol., Nonoichi
Abstract :
NOx from diesel exhaust gases can be removed efficiently by a combination of ozone injection and exhaust gas recirculation. In order to industrialize the system, it is necessary to develop NO control system, because NO concentration changes largely by engine output power. In this study, we constructed a NO control system without using NOx sensor. As for control method, we adopted two control methods; the one is an ozone control under predetermined rate of exhaust gas recirculation and the second one is an energy minimum control. The detail of automatic control methods are introduced in this paper. NO control experiments were carried out using 2.4 kVA diesel engine generator, and NO emissions were successfully controlled by the system.
Keywords :
diesel engines; diesel-electric generators; exhaust systems; nitrogen compounds; ozone; pollution control; NO; automatic control method; diesel engine generator; diesel exhaust gas; energy minimum control; exhaust gas recirculation; ozone injection; Automatic control; Automatic generation control; Control systems; Diesel engines; Electrical equipment industry; Gases; Industrial control; Power generation; Temperature control; Valves;
Conference_Titel :
Industry Applications Society Annual Meeting, 2008. IAS '08. IEEE
Conference_Location :
Edmonton, Alta.
Print_ISBN :
978-1-4244-2278-4
Electronic_ISBN :
0197-2618
DOI :
10.1109/08IAS.2008.121