• DocumentCode
    3211832
  • Title

    Transient Resistive Wallwake for Very Short Bunches

  • Author

    Stupakov, G.V.

  • Author_Institution
    Stanford Linear Accelerator Center, Stanford University, Stanford, CA 94309
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    2926
  • Lastpage
    2928
  • Abstract
    The catch up distance for the resistive wall wake in a round pipe is approximately equal to the square of the pipe radius divided by the bunch length. The standard formulae for this wake are applicable at distances much larger than the catch up distance. In this paper, we calculate the resistive wall wake at distances compared with the catch up distance assuming a constant wall conductivity.
  • Keywords
    Boundary conditions; Conductivity; Linear accelerators; Optical modulation; Optical propagation; Optical pulse generation; Proposals; Pulse modulation; Steady-state; X-ray lasers;