DocumentCode :
3213072
Title :
Comparative study of current vector control performance of alternate fault tolerant inverter topologies for three-phase PM brushless ac machine with one phase open - circuit fault
Author :
Hoang, Khoa Dang ; Zhu, Z.Q. ; Foster, Martin P. ; Stone, David A.
Author_Institution :
Deparment of Electronic and Electrical Engineering, University of Sheffield, Mappin Street, S1 3JD, UK
fYear :
2010
fDate :
19-21 April 2010
Firstpage :
1
Lastpage :
6
Abstract :
Reliability and fault tolerance of drive systems has received renewed research interest over last decade with several fault tolerant drive topologies and control schemes having been proposed and investigated. In this paper, the performance of hysteresis current vector control methodologies when applied to three common fault tolerant drive topologies has been investigated and compared theoretically and experimentally. Their advantages and limitations in terms of current value, current and torque ripples, and operating speed range etc. are considered and verified by both simulated and measured results. It is proven that by simply modifying the hysteresis current control methodology, the maximum torque per ampere (MTPA) can still be achieved in post-fault operation, albeit with potentially increased current value, low frequency current and torque ripples, and compromised speed operating range.
Keywords :
Fault tolerant control; maximum torque per ampere (MTPA) control; permanent magnet (PM) brushless AC (BLAC) machine; reliability; vector control;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics, Machines and Drives (PEMD 2010), 5th IET International Conference on
Conference_Location :
Brighton, UK
Type :
conf
DOI :
10.1049/cp.2010.0052
Filename :
5523742