DocumentCode :
3213613
Title :
Sensor and open-phase fault detection and isolation for three-phase AC drives
Author :
Meinguet, Fabien ; Gyselinck, Johan
Author_Institution :
BEAMS Department, Université Libre de Bruxelles (ULB), Brussels, Belgium
fYear :
2010
fDate :
19-21 April 2010
Firstpage :
1
Lastpage :
6
Abstract :
This paper deals with an on-line fault detection and isolation method for three-phase AC drives. The method is based on the detection of the stator current positive- and negative-sequence fundamental components expressed in the stationary αβ reference frame. These components allow calculating two fault indices used for the detection and isolation of an open-phase fault and a sensor fault, i.e. a disconnected sensor. The decision criterion is based on the CUSUM algorithm. The method includes a phase locked-loop performing the frequency adaptation needed to achieve fault detection on a wide speed range and even during speed transient. An experimental validation of the proposed method showing its effectiveness is carried out.
Keywords :
condition monitoring; electric machines; on-line diagnosis;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics, Machines and Drives (PEMD 2010), 5th IET International Conference on
Conference_Location :
Brighton, UK
Type :
conf
DOI :
10.1049/cp.2010.0029
Filename :
5523791
Link To Document :
بازگشت