Title :
Study of the application of the turbine flowmeter
Author :
Gang, Li ; Qiao-zhen, Li ; Hai-peng, Zhang
Author_Institution :
Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
Abstract :
Because of high accuracy, excellent repeatability and low pressure drop, turbine flowmeter is widely used in industry to measure gas or liquid flow. However, the disadvantage in linearity restricts its application. A new method, called piecewise linearity means, is discussed in paper. By using the new method, the flow range of the turbine flowmeter can be enlarged easily. A comparison between average meter factor and piecewise linearity means is present. This method can also be used in other sensors that output pulse signal.
Keywords :
flow measurement; flow sensors; flowmeters; piecewise linear techniques; average meter factor; flow range; gas flow measurement; liquid flow measurement; low pressure drop; piecewise linearity; pulse signal; repeatability; sensors; turbine flowmeter application; Turbines; application; turbine flow transducer; wide flow range;
Conference_Titel :
Electronics and Optoelectronics (ICEOE), 2011 International Conference on
Conference_Location :
Dalian, Liaoning
Print_ISBN :
978-1-61284-275-2
DOI :
10.1109/ICEOE.2011.6013404