• DocumentCode
    3214383
  • Title

    Data logger apparatus for stray current measurement of subway and power line

  • Author

    Bae, Jeong-Hyo ; Ha, Yoon-Cheol ; Ha, Tae-Hyun ; Lee, Hyun-Goo ; Kim, Dae-Kyeong ; Lee, Jae-Duck

  • Author_Institution
    Electr. Power Res. Lab., Korea Electrotechnology Res. Inst., Changwon, South Korea
  • Volume
    2
  • fYear
    2004
  • fDate
    2-6 Nov. 2004
  • Firstpage
    1563
  • Abstract
    In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in Korea. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.
  • Keywords
    corrosion; data loggers; electric current measurement; interference; pipes; power cables; data logger apparatus; electrical corrosion; gas explosion; gas pipeline; metallic structures; oil pipeline; power line; soil pollution; subway stray current measurement; water pipeline; Accidents; Corrosion; Current measurement; Explosion protection; Petroleum; Pipelines; Pollution measurement; Power system protection; Soil measurements; Soil pollution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE
  • Print_ISBN
    0-7803-8730-9
  • Type

    conf

  • DOI
    10.1109/IECON.2004.1431813
  • Filename
    1431813