Abstract
In the paper a number of factors affecting PSS electrodes erosion are considered. The basic modes of arc discharge and external factors affecting the thyratrons service time in this installations include the following four major ones: A - discharge without oscillations (aperiodic current), B - operation with current oscillations, C - operation with excess of maximum permitted current. Besides, the influence of thyratron switching circuit parameters on the service time becomes extremely important when the fourth factor D - Lorentz force appears to be considered. The data of life tests for the most powerful thyratrons TDII-200k/25 and TDIl-50k/45 allow to give the recommendations on improvement of the thyratrons operation reliability.
Keywords
pulsed power switches; thyratrons; Lorentz force; TDI-type pseudospark switches; TDII- 200k/25; TDIl-50k/45; current oscillations; electrodes erosion; installations; life tests; operation reliability; pulsed power applications; thyratron switching circuit; Laser fusion; Laser modes; Plasma accelerators; Plasma applications; Plasma confinement; Plasma materials processing; Plasma temperature; Power lasers; Switches; Thyratrons;
fLanguage
English
Publisher
ieee
Conference_Titel
Plasma Science - Abstracts, 2009. ICOPS 2009. IEEE International Conference on
Conference_Location
San Diego, CA
ISSN
0730-9244
Print_ISBN
978-1-4244-2617-1
Type
conf
DOI
10.1109/PLASMA.2009.5227466
Filename
5227466
Link To Document