DocumentCode
3215766
Title
Development and characterisation of self pinch and rod pinch diodes at 1.9 MEV
Author
Etchessahar, B. ; Nicolas, R. ; Rosol, R.
Author_Institution
Commissariat a l´´Energie Atomique, Polygone d´´Experimentation de Moronvilliers, Pontfaverger-Moronvilliers, France
fYear
2009
fDate
1-5 June 2009
Firstpage
1
Lastpage
1
Abstract
Summary form only given. Angelixl is a CEA flash X-ray facility witch consist of a 1.6 MV Marx generator, a 2 switches transmission line and a self magnetically pinched (SMP) diode2. In order to improve its radiographic performances, the Angelix generator has been upgraded to deliver a 1.9 MV diode peak voltage. Capacitors have been added into the Marx tank, using new insulators, and the main switch has been adapted. The geometric parameters of the SMP diode have been optimized from several flashes to produce the highest dose and the lowest spot size. This experimental campaign has shown that the factor of merits (FOM = dose/spot_size2) has been increased by 70 % for this SMP diode. Moreover, by an inversion of the Marx charge voltage polarity, a positive polarity rod pinch (RP) diode2 has been set up, replacing the SMP diode. The RP diode consists of a small diameter (less than 2 mm) cylindrical anode extending through a thin annular cathode. This diode has shown good radiographic performances at 1 to 2.3 MeV3. Its main interest is a spot size reduced to about 1 mm. Actually many flashes have been carried out in order to better understand the RP diode physics and to find the configuration delivering the best FOM. Several geometric parameters have been varied including: anode and cathode radii, rod length and position relative to the cathode, anode/cathode and power flow gaps. Different materials have been tested for the rod (W, Ta, Au, AL) with different surface conditions. More thanl rad at lm with a 1 mm spot size was obtained. Diagnostics used for theses experiments were electrical diagnostics (Bdot probes and resistive divisors), rolled edge and radiographic films (spot size), FLi dosimeters, PIN diodes, pinhole cameras and a high speed CCD camera.
Keywords
pinch effect; plasma diodes; plasma probes; pulse generators; pulsed power supplies; Angelixl; Bdot probes; Marx charge voltage polarity; Marx generator; electrical diagnostics; radiographic films; radiographic performances; resistive divisors; rod pinch diodes; rolled edge; self magnetically pinched diode2; self pinch; Anodes; Capacitors; Cathodes; Charge-coupled image sensors; Diodes; Magnetic switching; Power transmission lines; Radiography; Switches; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Plasma Science - Abstracts, 2009. ICOPS 2009. IEEE International Conference on
Conference_Location
San Diego, CA
ISSN
0730-9244
Print_ISBN
978-1-4244-2617-1
Type
conf
DOI
10.1109/PLASMA.2009.5227519
Filename
5227519
Link To Document