• DocumentCode
    3215938
  • Title

    Experience with the EPICS PV Gateway at the APS

  • Author

    Evans, Kenneth ; Smith, Martin

  • Author_Institution
    ANL, Argonne, IL 60439, U.S.A.
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    3621
  • Lastpage
    3623
  • Abstract
    The EPICS Process Variable Gateway [1] has become a stable, high-performance application that provides access to process variables while minimizing the impact on critical Input-Output Controllers (IOCs) and implementing additional access security. The additional access security typically prevents write access but is highly configurable. The Advanced Photon Source (APS) currently uses 40 Gateways running on 11 workstations to provide access to the machine subnet from the offices and for the individual experimental teams. These include reverse Gateways that allow administration of all 40 APS Gateways from a single MEDM [2] screen, even though the Gateways are running on separate networks. This administration includes starting, stopping, making and viewing reports, and viewing and editing access security files. There is one Gateway that provides process variable renaming. This paper provides an overview of the Gateways at the APS and describes the procedures that have been set up to use and administer them.
  • Keywords
    Contracts; Linear particle accelerator; Linux; Monitoring; Personnel; Robustness; Security; Testing; Video equipment; Workstations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591559
  • Filename
    1591559