DocumentCode
3218091
Title
Effect comparison of smoke control mode in high-rise building aisle
Author
Wei, Zhang ; Jiapeng, He
Author_Institution
Sch. of Urban Constr. & Safety Eng., Nanjing Univ. of Technol., Nanjing, China
fYear
2011
fDate
22-24 April 2011
Firstpage
5892
Lastpage
5895
Abstract
In order to study the effect of common smoke control model, the numerical simulation combined with the full size experimental have been used to analyze effect of several modes, which composed with the smoke screen, mechanical smoke and air curtain, and the smoke temperature distribution, concentration distribution, and smoke down time between these model is compared. The results show that smoke preventing air curtain and pressurization in atria, with two smoke vents in aisle has the best mode of smoke control effect, which has exhaust efficiency about 74.52% It not only can let smoke out timely, but also can guarantee safe evacuation environment in atria.
Keywords
building management systems; fires; smoke; air curtain; concentration distribution; high-rise building aisle; mechanical smoke; numerical simulation; safe evacuation environment; smoke control mode; smoke down time; smoke screen; smoke temperature distribution; Atmospheric modeling; Buildings; Fires; Mathematical model; Numerical models; Temperature distribution; Vents; experiment; high-rise building; numerical simulation; smoke control;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Technology and Civil Engineering (ICETCE), 2011 International Conference on
Conference_Location
Lushan
Print_ISBN
978-1-4577-0289-1
Type
conf
DOI
10.1109/ICETCE.2011.5774369
Filename
5774369
Link To Document