Title :
Dual Power Supplies for PEP-II Injection Kickers
Author :
Olszewski, J. ; Decker, F.J. ; Iverson, R.H. ; Kulikov, A. ; Pappas, C.
Author_Institution :
SLAC, Menlo Park, CA 94025, U.S.A.
Abstract :
Originally the PEP-II injection kickers where powered by one power supply. Since the kicker magnets where not perfectly matched, the stored beam got excited by about 7% of the maximum kicker amplitude. This led to luminosity losses which were especially obvious for trickle injection when the detector is on for data taking. Therefore two independent power supplies with thyratrons in the tunnel next to the kicker magnet were installed. This also reduces the necessary power by about a factor of four since there are no long cables that have to be charged. The kickers are now independently adjustable to eliminate any non-closure of the kicker system and therefore excitation of the stored beam. Setup, commissioning and fine tuning of this system are discussed.
Keywords :
Cables; Capacitors; Magnetic modulators; Magnets; Optical reflection; Power supplies; Reservoirs; Thyratrons; Timing; Voltage;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1591711