DocumentCode
3218671
Title
Dual Power Supplies for PEP-II Injection Kickers
Author
Olszewski, J. ; Decker, F.J. ; Iverson, R.H. ; Kulikov, A. ; Pappas, C.
Author_Institution
SLAC, Menlo Park, CA 94025, U.S.A.
fYear
2005
fDate
16-20 May 2005
Firstpage
4045
Lastpage
4047
Abstract
Originally the PEP-II injection kickers where powered by one power supply. Since the kicker magnets where not perfectly matched, the stored beam got excited by about 7% of the maximum kicker amplitude. This led to luminosity losses which were especially obvious for trickle injection when the detector is on for data taking. Therefore two independent power supplies with thyratrons in the tunnel next to the kicker magnet were installed. This also reduces the necessary power by about a factor of four since there are no long cables that have to be charged. The kickers are now independently adjustable to eliminate any non-closure of the kicker system and therefore excitation of the stored beam. Setup, commissioning and fine tuning of this system are discussed.
Keywords
Cables; Capacitors; Magnetic modulators; Magnets; Optical reflection; Power supplies; Reservoirs; Thyratrons; Timing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN
0-7803-8859-3
Type
conf
DOI
10.1109/PAC.2005.1591711
Filename
1591711
Link To Document