    Dual Power Supplies for PEP-II Injection Kickers

  • Author

    Olszewski, J. ; Decker, F.J. ; Iverson, R.H. ; Kulikov, A. ; Pappas, C.

  • Author_Institution
    SLAC, Menlo Park, CA 94025, U.S.A.
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    4045
  • Lastpage
    4047
  • Abstract
    Originally the PEP-II injection kickers where powered by one power supply. Since the kicker magnets where not perfectly matched, the stored beam got excited by about 7% of the maximum kicker amplitude. This led to luminosity losses which were especially obvious for trickle injection when the detector is on for data taking. Therefore two independent power supplies with thyratrons in the tunnel next to the kicker magnet were installed. This also reduces the necessary power by about a factor of four since there are no long cables that have to be charged. The kickers are now independently adjustable to eliminate any non-closure of the kicker system and therefore excitation of the stored beam. Setup, commissioning and fine tuning of this system are discussed.
  • Keywords
    Cables; Capacitors; Magnetic modulators; Magnets; Optical reflection; Power supplies; Reservoirs; Thyratrons; Timing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591711
  • Filename
    1591711