Abstract
GeV upgrade prototype cryomodule Renascence have been fabricated at JLab and tested individually. This set includes four of the “Low Loss” (LL) design and eight of the “High Gradient” (HG) design. The fabrication strategy was an efficient mix of batch job-shop component machining and in-house EBW, chemistry, and final-step machining to meet mechanical tolerances. Process highlights will be presented. The cavities have been tested at 2.07 K, the intended CEBAF operating temperature. Performance exceeded the tentative design requirement of 19.2 MV/m CW with less than 29 W dynamic heat dissipation. These results, as well as the HOM damping performance are presented.
Keywords
Business continuity; Damping; Fabrication; Flanges; Machining; Mercury (metals); Niobium; Prototypes; Testing; Welding;