DocumentCode :
3219010
Title :
Electron emission phenomenon of cathode evaporator
Author :
Yang Jing-xin ; Yin Sheng-yi ; Zhang Hong-lai ; Wang Yu ; Wang Xin-Xin
Author_Institution :
Key Lab. of High Power Microwave Sources & Technol., Chinese Acad. of Sci., Beijing, China
fYear :
2010
fDate :
14-16 Oct. 2010
Firstpage :
197
Lastpage :
198
Abstract :
In order to study the electron emission phenomenon of evaporator of an impregnated cathode, a special device is designed, which includes barium tungsten cathode, tungsten receiver, vacuum system, data acquisition unit, etc. The characteristics of the impregnated cathode are as follows: Φ 8.0 mm x 2.5 mm, 25% porosity of porous tungsten matrix, 6BaO/CaO/2Al2O3 impregnant. While the tungsten receiver cathode is a polished polycrystalline tungsten wafer with the size of Φ 3.5 mm x 1.0 mm. The relative distance between the two cathodes is 1.0 mm.
Keywords :
barium; electron emission; polishing; porosity; porous materials; tungsten; Ba; W; barium tungsten cathode; cathode evaporator; data acquisition unit; electron emission phenomenon; impregnated cathode; polished polycrystalline tungsten wafer; porosity; porous tungsten matrix; tungsten receiver cathode; vacuum system;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Vacuum Electron Sources Conference and Nanocarbon (IVESC), 2010 8th International
Conference_Location :
Nanjing
Print_ISBN :
978-1-4244-6645-0
Type :
conf
DOI :
10.1109/IVESC.2010.5644339
Filename :
5644339
Link To Document :
بازگشت