• DocumentCode
    3222887
  • Title

    A comparative analysis of voltage magnitude deviation and unbalance on standard and premium efficient induction motors

  • Author

    Agamloh, E.B. ; Peele, Scott ; Grappe, Joe

  • Author_Institution
    Adv. Energy, Raleigh, NC, USA
  • fYear
    2012
  • fDate
    17-21 June 2012
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    Experimental tests were carried out to determine if there are any noticeable differences in the way premium and standard efficiency motors operate under abnormal voltage conditions such as over voltage under voltage and voltage unbalance. The results for four motors are compared in terms of efficiency and overcurrent conditions and the differences in the performance of the motors are highlighted. In addition, two 3-phase motors were connected to a single phase variable frequency drive and the effect of voltage magnitude deviations on system efficiency was investigated.
  • Keywords
    induction motors; overvoltage; variable speed drives; 3-phase motors; abnormal voltage conditions; induction motors; overcurrent conditions; overvoltage; standard unbalance; variable frequency drive; voltage magnitude deviation; voltage unbalance; Induction motors; Industries; Rotors; Standards; Thermal stability; Voltage control; Voltage measurement; Induction motors; voltage unbalance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulp and Paper Industry Technical Conference (PPIC), Conference Record of 2012 Annual IEEE
  • Conference_Location
    Portland, OR
  • ISSN
    0190-2172
  • Print_ISBN
    978-1-4673-0406-1
  • Type

    conf

  • DOI
    10.1109/PPIC.2012.6293004
  • Filename
    6293004