DocumentCode :
3224047
Title :
Automatic detection of the intimal and the adventitial layers of the common carotid artery wall in ultrasound B-mode images using snakes
Author :
Cheng, Da-Chuan ; Schmidt-Trucksäss, Arno ; Cheng, Kuo-Sheng ; Sandrock, Markus ; Pu, Qin ; Burkhardt, Hans
Author_Institution :
Inst. of Biomed. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
fYear :
1999
fDate :
1999
Firstpage :
452
Lastpage :
457
Abstract :
This study presents a novel automatic system for detecting the intimal and adventitial layers of the far common carotid artery (CCA) by applying snake techniques. Cohen´s snake is also modified and some criteria are added for our applications. In addition, the oscillating problem of using snakes is solved by properly choosing the time step from analysis of the frequency response of the filters. The snake scheme combined with a time diminishing gravity window and an external force makes it possible to detect the intima-media complex of the far CCA. Besides, a cost function assists the snake in selecting the optimal shape of adventitia layer. This mechanism is also helpful when there are plaques on the CCA wall. Moreover, this study compares the proposed snake and ziplock snake with respect to the manual extraction contour. According to that comparison, the system can automatically detect the intimal and adventitial layers. In addition to that it does not need any manual correction and it is noise-resistant; the proposed system allows a user to quantitatively measure an important predictor of heart infarction and strokes
Keywords :
biomedical ultrasonics; cardiology; edge detection; feature extraction; filtering theory; frequency response; medical image processing; optimisation; Cohen´s snake; adventitial layers; automatic detection; common carotid artery wall; cost function; external force; far CCA; filters; frequency response; heart infarction; intima-media complex; intimal layers; manual extraction contour; optimal shape; oscillating problem; plaques; prediction; quantitative measurement; strokes; time diminishing gravity window; time step; ultrasound B-mode images; ziplock snake; Active contours; Biomedical engineering; Biomedical imaging; Carotid arteries; Computer science; Filters; Gravity; Hospitals; Myocardium; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image Analysis and Processing, 1999. Proceedings. International Conference on
Conference_Location :
Venice
Print_ISBN :
0-7695-0040-4
Type :
conf
DOI :
10.1109/ICIAP.1999.797637
Filename :
797637
Link To Document :
بازگشت