DocumentCode
3225382
Title
Broadband detection of radiating moments using the TEM-cell and a phase-calibrated oscilloscope
Author
Gillon, Renaud ; Bako, Niko ; Baric, Adrijan
Author_Institution
ON Semicond. Belgium, Oudenaarde, Belgium
fYear
2013
fDate
15-18 Dec. 2013
Firstpage
27
Lastpage
32
Abstract
The differential and common-mode signals across the TEM-cell ports are known to be correlated with magnetic and electric dipoles respectively. Historically, the absence of phase information in the measurements complicated the identification procedure for radiating moments. Using a phase-calibrated scope, this paper demonstrates a broadband and effective method for the extraction of radiating moments.
Keywords
calibration; magnetic moments; oscilloscopes; TEM-cell ports; broadband detection; common-mode signals; differential signals; electric dipoles; identification procedure; magnetic dipoles; phase information; phase-calibrated oscilloscope; radiating moments; Calibration; Conferences; Electromagnetic compatibility; Equations; Integrated circuits; Magnetic moments; Oscilloscopes;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility of Integrated Circuits (EMC Compo), 2013 9th Intl Workshop on
Conference_Location
Nara
Type
conf
DOI
10.1109/EMCCompo.2013.6735167
Filename
6735167