Abstract :
Some basic properties of recycled steel fiber aggregate were tested, such as surface features, water absorption, apparentensity, crushing index, cube compressive strength and so on. Recycled steel fiber aggregate were used to replace the natural aggregate by 0%, 25%, 50% and 100% proportion to make concrete. Afterward, compressive strength, splitting tensile strength and flexural strength were investigated at ages 3, 7 and 28 days. The results showed that thorn appearance of recycled steel fiber aggregate makes packing density decrease, crushing value and absorption increase. The compressive strength, splitting tensile strength and flexural strength of the recycled concrete depend on the mix proportions. Generally, the strength of recycled concrete can be 15-25% lower than that of concrete made with virgin aggregate.
Keywords :
aggregates (materials); bending strength; compressive strength; concrete; fibres; recycling; steel; tensile strength; apparent ensity; crushing index; cube compressive strength; flexural strength; natural aggregate; packing density; recycled steel fiber aggregate; recycled steel fiber concrete; splitting tensile strength; surface features; time 28 day; time 3 day; time 7 day; water absorption; Aggregates; Concrete; Educational institutions; Optical fiber testing; Steel; Three dimensional displays; recycled aggregate; recycled concrete; steel fiber reinforced concrete;
Conference_Titel :
Electric Technology and Civil Engineering (ICETCE), 2011 International Conference on
Conference_Location :
Lushan
Print_ISBN :
978-1-4577-0289-1
DOI :
10.1109/ICETCE.2011.5774777