Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation
Author :
Gilland, D.R. ; Jaszczak, R.J. ; Turkington, T.G. ; Coleman, R.E.
Author_Institution :
Dept. of Radiol., Duke Univ. Med. Center, Durham, NC, USA
Volume :
2
fYear :
1997
fDate :
9-15 Nov 1997
Firstpage :
1556
Abstract :
This study compared two approaches for acquiring transmission computed tomography (TCT) data for SPECT nonuniform attenuation compensation. One approach, which has been implemented in commercial SPECT systems, acquires the TCT and SPECT data simultaneously using a scanning transmission line source, dual head SPECT system and parallel beam collimation (PB-sim). The other approach acquires the TCT and SPECT data sequentially using long focus, off-set fan beam collimation with a non-scanning line source and a triple head system (FB-seq). The two systems were compared based on (a) the noise level of the TCT data, (b) the spatial resolution of the TCT data, and (c) the quality of reconstructed TCT and SPECT images of a thorax phantom. For the thorax phantom data, a fast TCT scan was used (2 min.) and total scan time (TCT and SPECT) was the same for the two systems. The results from the TCT noise measurements showed that for the source activities used here (400 mCi for PB-sim, 56 mCi for FB-seq), PB-sim had higher count density in the lung region whereas FB-seq had higher in the heart and liver regions. The measured TCT spatial resolution for the two systems was comparable in the axial direction but far superior with FB-seq in the transaxial direction. This difference in resolution was apparent in the reconstructed TCT images. The SPECT images from the two systems demonstrated the effects of attenuation compensation
Keywords :
data acquisition; gamma-ray absorption; image reconstruction; image resolution; medical image processing; single photon emission computed tomography; 0.056 ci; 2 min; SPECT nonuniform attenuation compensation; attenuation compensation effects; axial direction; count density; medical diagnostic imaging; noise level; nonscanning line source; nuclear medicine; offset fan beam collimation; reconstructed images quality; source activities; spatial resolution; thorax phantom; transaxial direction; transmission acquisition approaches; triple head system; Attenuation; Collimators; Computed tomography; Focusing; Image reconstruction; Imaging phantoms; Magnetic heads; Spatial resolution; Thorax; Transmission lines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1997. IEEE
Conference_Location :
Albuquerque, NM
ISSN :
1082-3654
Print_ISBN :
0-7803-4258-5
Type :
conf
DOI :
10.1109/NSSMIC.1997.670615
Filename :
670615
Link To Document :
بازگشت