• DocumentCode
    3229117
  • Title

    Solid state simulation of movements for the test of volumetric intrusion detectors

  • Author

    Williams, Ian ; Berentsen, Martin ; Rexfort, Claudia

  • Author_Institution
    Dept. of Commun. Eng., Gerhard-Mercator Univ., Duisburg, Germany
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    95
  • Lastpage
    100
  • Abstract
    The determination of sensitivity changes of volumetric intrusion detectors by means of walk tests is current practice in many test laboratories but suffers from repeatability. This situation is of special importance in relation to approval tests. A concept was worked out in order to determine the response threshold value of intrusion detectors by means of a test apparatus which fits in a normal room and is able to test even dual technology detectors. The apparatus utilises a solid state design for passive infrared detector testing as well as for the test of Doppler detectors
  • Keywords
    access control; digital simulation; infrared detectors; safety systems; testing; Doppler detectors; dual technology detectors; movement simulation; passive infrared detector testing; response threshold value; sensitivity changes; solid state simulation; test laboratories; volumetric intrusion detector testing; walk tests; Infrared detectors; Laboratories; Legged locomotion; Orbital robotics; Smoke detectors; Solid modeling; Solid state circuits; Space technology; System testing; Test equipment;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Security Technology, 1999. Proceedings. IEEE 33rd Annual 1999 International Carnahan Conference on
  • Conference_Location
    Madrid
  • Print_ISBN
    0-7803-5247-5
  • Type

    conf

  • DOI
    10.1109/CCST.1999.797901
  • Filename
    797901