DocumentCode :
3229145
Title :
Assessment of the state of mica-resin insulation using PD charge analysis and dielectric loss measurements
Author :
Ziomek, W. ; Moscicka-Grzesiak, H. ; Kuffel, E.
Author_Institution :
Inst. of Electr. Power Eng., Poznan Tech. Univ., Poland
Volume :
2
fYear :
1996
fDate :
20-23 Oct 1996
Firstpage :
492
Abstract :
The paper presents the results describing insulation conditions of glass fabric-mica paper-epoxy resin material using PD charge analysis and dielectric loss measurements. The partial discharges (PD) charge was measured using a PD detector and a multichannel pulse-height analyzer. Parameters characterizing the state of the insulating material which were analyzed included total PD charge, maximum PD charge, charge of the most intensive PD pulses, the number of PD pulses recorded during observation time and dielectric loss. The experiments were carried out for two groups of samples of the insulating material: (i) prepared according to the production procedure required, (ii) overheated during the preparation process. The research showed that material defects can be detected more accurately by multichannel analysis of PD charge, than tan delta measurements
Keywords :
dielectric losses; epoxy insulation; insulation testing; mica; partial discharges; pulse height analysers; PD charge analysis; dielectric loss measurements; insulation conditions; mica-resin insulation; multichannel pulse-height analyzer; overheated sample; Charge measurement; Current measurement; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Dielectrics and electrical insulation; Glass; Partial discharges; Pulse measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
Conference_Location :
Millbrae, CA
Print_ISBN :
0-7803-3580-5
Type :
conf
DOI :
10.1109/CEIDP.1996.564517
Filename :
564517
Link To Document :
بازگشت