DocumentCode
3229335
Title
Ultrasound-based Speckle Tracking for 3D Strain estimation of the Arterial wall — An experimental validation study in a tissue mimicking phantom
Author
Larsson, Mats ; Kremer, Florence ; Heyde, Brecht ; Brodin, Lars-Ake ; D´hooge, J.
Author_Institution
Dept. of Cardiovascular Diseases, Catholic Univ. of Leuven, Leuven, Belgium
fYear
2011
fDate
18-21 Oct. 2011
Firstpage
725
Lastpage
728
Abstract
Arterial stiffness is an important risk factor for cardiovascular disease. As such, ultrasound-based methods have been proposed to assess arterial strain as a measure of stiffness. The aim of the current study was to validate our recently proposed speckle tracking (ST) algorithm to estimate the in-plane wall strain tensor in an experimental setup. Three polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties (2, 3 and 4 freeze-thaw cycles). The phantoms were connected to a pump, programmed to generate carotid flow profiles at peak flows of 7, 14, 21, 28 and 35 ml/s. Long and short-axis ultrasound images were obtained using a Vivid7 Dimension system. Radial, longitudinal and circumferential strains were estimated using the ST algorithm (kernel size: 2.7λ×2λ, normalized cross-correlation; spline inter-polation for subsample motion estimation; 40% window overlap). Sonomicrometry was used to acquire reference values of strain in the phantoms. Good agreement was found between the estimated radial, longitudinal and circumferential strain and the acquired reference strain. The correlation between estimated mean peak strain values and reference peak strain values was r = 0.92 (p <;0.001) for radial strain, r = 0.72 (p = 0.006) for longitudinal strain and r = 0.91 (p<;0.001) for circumferential strain.
Keywords
biomechanics; biomedical measurement; biomedical ultrasonics; blood vessels; cardiovascular system; diseases; elastic constants; image sampling; interpolation; medical image processing; motion estimation; phantoms; speckle; strain measurement; ultrasonic imaging; 3D strain estimation; Vivid7 Dimension system; arterial stiffness measurement; arterial wall; cardiovascular disease; carotid flow profiles; circumferential strains; freeze-thaw cycles; in-plane wall strain tensor; long-axis ultrasound images; longitudinal strains; mechanical properties; polyvinyl alcohol phantoms; pump; radial strains; short-axis ultrasound images; sonomicrometry; spline interpolation; subsample motion estimation; tissue mimicking phantom; ultrasound-based speckle tracking; Carotid arteries; Crystals; Phantoms; Speckle; Strain; Strain measurement; Ultrasonic imaging; Arterial strain; Carotid artery; Speckle tracking; Vessel phantom;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2011 IEEE International
Conference_Location
Orlando, FL
ISSN
1948-5719
Print_ISBN
978-1-4577-1253-1
Type
conf
DOI
10.1109/ULTSYM.2011.0176
Filename
6293377
Link To Document