• DocumentCode
    3232945
  • Title

    Effect of humidity on DC breakdown voltages in ambient air at high altitude

  • Author

    Chavarria, P. A Calva ; Robledo-Martinez, A.

  • Author_Institution
    Inst. Politecnico Nacional, Mexico City, Mexico
  • Volume
    2
  • fYear
    1996
  • fDate
    20-23 Oct 1996
  • Firstpage
    567
  • Abstract
    It is demonstrated that the IEC correction procedure is not adequate for direct-current voltage measurements at high altitude. This is mostly a consequence of the fact that the physical model employed, which is based on the field of propagation of streamers, fails to account for the combined effect of humidity and altitude. The experimental rod-plane results obtained by the authors are better modelled by an alternative semi-empirical model
  • Keywords
    electric breakdown; humidity; voltage measurement; DC breakdown voltage; IEC correction procedure; altitude; ambient air; direct-current voltage measurement; humidity; physical model; rod-plane geometry; semi-empirical model; streamer propagation; Atmosphere; Atmospheric modeling; Breakdown voltage; Electric breakdown; Electrodes; Humidity; IEC standards; Insulation; Sea measurements; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
  • Conference_Location
    Millbrae, CA
  • Print_ISBN
    0-7803-3580-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.1996.564535
  • Filename