Abstract
We have irradiated a n-side silicon microstrip detector with 55 MeV protons up to an equivalent fluence of 1×1015 p cm -2 high energy protons. We determine the median pulse height to be 0.7 fC at 180 V bias and deduce a depletion region of about 80 μm
Keywords
proton detection; proton effects; silicon radiation detectors; Si; depletion region; high energy protons; median pulse height; n-side silicon microstrip detector; proton irradiation; pulse height; Detectors; Microstrip; Particle beam measurements; Particle beams; Particle measurements; Protons; Pulse measurements; Silicon; Strips; Voltage;