• DocumentCode
    3233087
  • Title

    Evaluation of LV insulating systems in inverter fed electric motors by means of partial discharges

  • Author

    Boscolo, Antonio ; Rabach, Germano ; Visintin, Massimiliano

  • Author_Institution
    Dept. of Electrotechnics, Univ. of Trieste, Trieste
  • fYear
    2005
  • fDate
    7-9 Sept. 2005
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    A synthetic description of the phenomena induced by PWM inverter drive systems are reported and the parameters related to motor reliability are evaluated. The winding quality of brand new motors is addressed, specifically the integrity of the turn or the conductor insulation is checked by applying surge voltage stresses. Finally Partial Discharge (PD) measurements are carried out on an aged 800 kW motor: the outcomes are reported and discussed.
  • Keywords
    electric drives; electric motors; machine insulation; machine windings; partial discharge measurement; reliability; LV insulating systems; PWM inverter drive systems; conductor insulation; inverter fed electric motors; motor reliability; partial discharge measurements; partial discharges; power 800 kW; surge voltage stresses; synthetic description; winding quality; Aging; Conductors; Dielectrics and electrical insulation; Electric motors; Partial discharge measurement; Partial discharges; Pulse width modulation inverters; Stress; Surges; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Diagnostics for Electric Machines, Power Electronics and Drives, 2005. SDEMPED 2005. 5th IEEE International Symposium on
  • Conference_Location
    Vienna
  • Print_ISBN
    978-0-7803-9124-6
  • Electronic_ISBN
    978-0-7803-9125-3
  • Type

    conf

  • DOI
    10.1109/DEMPED.2005.4662503
  • Filename
    4662503