• DocumentCode
    3235049
  • Title

    Dual frequency imaging and therapeutic transducer using an acoustic band-pass filter for application to endoscopic surgery

  • Author

    Azuma, Takashi ; Kenmotsu, Hajime ; Hashidume, Makoto ; Umemura, Shin-ichiro

  • fYear
    2011
  • fDate
    18-21 Oct. 2011
  • Firstpage
    1645
  • Lastpage
    1648
  • Abstract
    A HIFU and imaging hybrid transducer with stacking structure for endoscopic application was described. In our previous study, a bi-laminar transducer involved an imaging and a therapeutic array transducers and a polymer layer working as an acoustic band-pass filter (ABPF) between both transducers was developed[1]. Because the ABPF passes through the lower frequency therapeutic beam and reflects the higher frequency imaging beam, the imaging array was isolated from the therapeutic transducer. Because this prototype transducer was designed to realize ultrasound clot solution, therapeutic output was lower than that of HIFU. In this study, frequency and power optimizations are required. Based on simulation optimization, a prototype transducer consisting of a spherical HIFU transducer and a concave imaging array stacking on the HIFU transducer was fabricated. The fractional bandwidth at -20 dB of imaging pulses was 100%. The transmittance of the HIFU beam through the imaging array was 0.6. The measured bandwidth of the imaging pulse is sufficient to obtain a high resolution US image. An estimated peak intensity of HIFU beam transmitted from the prototype structure was 60% higher than that of the conventional HIFU transducer with a center hole to mount the imaging array, whose outer diameter of aperture is the same as that of the prototype structure.
  • Keywords
    acoustic filters; band-pass filters; biomedical ultrasonics; endoscopes; image resolution; medical image processing; optimisation; surgery; ultrasonic imaging; ultrasonic transducer arrays; HIFU transducer; acoustic band-pass filter; bilaminar transducer; concave imaging array stacking; dual frequency imaging; endoscopic surgery application; frequency optimizations; high resolution ultrasound image; higher frequency imaging beam; low frequency therapeutic beam; polymer layer; power optimizations; simulation optimization; therapeutic array transducers; ultrasound clot solution; Acoustic beams; Acoustics; Apertures; Arrays; Imaging; Prototypes; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2011 IEEE International
  • Conference_Location
    Orlando, FL
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-1253-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2011.0409
  • Filename
    6293667